(4)
Lift the rear side of the developer unit up and
move the developer material to the front side
of the mixer under the developer sleeve.
(5)
Pour in more developer until the mixer [1]
under the developer sleeve is full.
(6)
Pour all the remaining developer material
into another mixer [1].
Notes:
•
Fill the developer material in the mixer
section under the developer sleeve as
much as possible.
•
Check if the developer does not adhered
to the joint of the upper cover.
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-229
Fig. 4-230
Fig. 4-231
e-STUDIO2555C/3055C/3555C/4555C/5055C
4 - 81
DISASSEMBLY AND REPLACEMENT