Step
Check item
9
Reinstall the removed SYS
board and then replace the
LGC board.
Perform automatic gamma
adjustment after the board is
replaced.
Replace parts
LGC board
SYS board
[CE50] Temperature/humidity sensor abnormality
Classification
Image control related service call
Check Item
Temperature/humidity sensor
Replacement part
Temperature/humidity sensor
LGC board
[CE60] Drum thermistor 2 abnormality
Classification
Copy process related service call
Check item
Drum thermistor 2
LGC board
Replace parts
Drum thermistor 2
LGC board
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Result
Temperature/humidity sensor abnormality: The output value of
this sensor is out of a specified range.
Check the connectors and harnesses between the temperature/
humidity sensor and LGC board (CN369).
The output value of the drum thermistor 2 is out of a specified
range.
Thermistor check (Perform the input check: 03-
[COPY]ON/[4])
Connector check (J1054)
Harness check
Connector check (CN370)
Harness check
8 - 197