Cause/Section
Step
Fuser unit
1
2
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
Check item
Installed position of the fuser unit
The installation position of the fuser
unit paper entrance guide
8 - 324
Measures
Loosen the 1 screw [1] on the fuser
unit guide rail (front). Remove 1
screw [2]. Change its position to the
adjustment hole [3] and move the
fuser unit guide rail (front) up or
down (one step). (Fig.8-35)
* There is a 1-mm scale [4].
Following are the adjustment
procedure of the fuser unit paper
inlet guide. (Fig.8-36)
Notes:
Confirm the positions of the
screws before removing the
inlet guide.
Check if the inlet guide is
attached horizontally by
checking the scales for the
inlet guide.
(1)
Take off the fuser unit.
(2)
Remove the 2 screws of the
paper entrance guide [1], and
then secure them to the holes
next to the original ones.
(3)
Vertically move the paper
entrance guide to the upper
direction of the figure so that it
is separated by approx. 0.5
mm from the fuser belt.
(4)
In the condition of step (3),
check whether white void
occurs or not.
(5)
If white void still persists,
move the paper entrance
guide by 0.1 to 0.2 mm to
upward or downward.
Notes:
1. Be careful not to move the
paper entrance guide too
much, for this could cause
paper wrinkling.
2. If paper wrinkling does
occur, return the position of
the paper entrance guide
to the condition of step (3).