Notes:
After a new fuser belt is installed in the
frame of the fuser unit, be sure to remove
the protection sheet [5] attached to the
belt to avoid damaging or staining its
surface.
Be careful that the thermistor [6] of the
fuser unit is not deformed when it is
placed after the removal of the fuser belt.
The thermistor may be deformed if it is
made to come to the lower side by turning
the fuser unit.
4.9.9

Fuser belt lubricating sheet / Fuser belt pad

(1)
Remove the fuser belt.
 P. 4-153 "4.9.8 Fuser belt"
(2)
Loosen 4 screws (M2.6). Remove 1 screw
[2] (M2.6).
Notes:
When handling the inside of the fuser belt
unit, position a towel or cushion so that no
pressure is applied to the shield [1].
Be sure to secure the 5 screws (M2.6),
otherwise they come off and this will
cause the damage of the fuser belt.