Download Print this page

Toshiba e-STUDIO 2555C Service Manual page 161

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

Notes:
When removing the flat cable, change the
lever position so that the connector is
released, and remove the flat cable by
lifting it up slightly (approx. 7 degrees) as
shown in the right figure.
When connecting the flat cable to the
connector, insert the flat cable straightly
and lock it securely. Confirm that the tabs
are in the positions shown in the right
figure.
Notes:
Only rotation movement (max. 90 degrees) is
allowed for the locking lever of the connector.
Never apply excessive force to the lever. In
addition, be sure not to pull the lever or not to
catch its top with your nails.
Notes:
When installing the flat cable, be careful
not to insert it at an angle.
Do not apply pressure to or damage the
edge of the flat cable.
When installing the flat cable, do not push
it in strongly.
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Tab
Guide
FFC
Connector
Fig. 4-66
Fig. 4-67
Fig. 4-68
e-STUDIO2555C/3055C/3555C/4555C/5055C
4 - 25
Lever position: Locked
Lever position: Released
DISASSEMBLY AND REPLACEMENT
4

Hide quick links:

Advertisement

loading