Download Print this page

Toshiba e-STUDIO 2555C Service Manual page 564

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

Error code
Classification
E712
RADF jam
E714
E721
E722
E724
E725
E726
E731
E860
E870
E871
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
Contents
Jam not reaching the original registration
sensor: The original fed from the original
feeding tray does not reach the original
registration sensor.
Feed signal reception jam: The feed signal is
received even no original exists on the original
feeding tray.
Jam not reaching the read sensor: The original
does not reach the read sensor after it has
passed the registration sensor (when scanning
obverse side) or the reverse sensor (when
scanning reverse side).
Jam not reaching the original exit/reverse
sensor (during scanning): The original which
passed the read sensor does not reach the
original exit/reverse sensor when it is
transported from the scanning section to exit
section.
Stop jam at the original registration sensor: The
trailing edge of the original does not pass the
original registration sensor after its leading
edge has reached this sensor.
Stop jam at the read sensor: The trailing edge
of the original does not pass the read sensor
after its leading edge has reached this sensor.
Transport/exit signal reception jam: RADF
receives the transport/exit reception signal
from the equipment when no original is at the
exposure waiting position.
Stop jam at the original exit/reverse sensor:
The trailing edge of the original does not pass
the original exit/reverse sensor after its leading
edge has reached this sensor.
RADF jam access cover open: The RADF jam
access cover has opened during RADF
operation.
RADF open jam: RADF has opened during
RADF operation.
Cover open jam in the read ready status
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
8 - 8
Troubleshooting
P. 8-72
P. 8-72
P. 8-73
P. 8-73
P. 8-74
P. 8-74
P. 8-75
P. 8-75
P. 8-76
P. 8-76
P. 8-76

Hide quick links:

Advertisement