4.6.17
Needle electrode
(1)
Remove the main charger cleaner.
P. 4-95 "4.6.16 Main charger cleaner"
(2)
Pull out the lever [1] and remove the needle
electrode [2] together with the lever [1].
Notes:
When installing the needle electrode, be sure
of the following:
•
Be sure that its needle comes at its top
side.
•
Hook the needle electrode and the spring
on both front and rear terminals securely.
•
Do not twist the needle electrode.
•
Do not touch the needle electrode directly
with bare hands.
4.6.18
Drum old/new detection switches (SW9, SW10, SW11, SW12) and
Developer unit old/new detection switches (SW13, SW14, SW15,
SW16)
(1)
Remove the transfer belt unit.
P. 4-130 "4.7.3 Transfer belt unit (TBU)"
(2)
Remove The Cleaner Unit.
P. 4-87 "4.6.9 Cleaner unit"
(3)
Remove The Toner Motor Assembly.
P. 4-110 "4.6.30 Toner motor assembly"
(4)
Remove 3 screws, release 5 upper latches
[1], and then take off the toner cartridge
holder [2].
e-STUDIO2555C/3055C/3555C/4555C/5055C
DISASSEMBLY AND REPLACEMENT
Fig. 4-273
Fig. 4-274
Fig. 4-275