Error
Movable tray shift motor (M1)
Stack top detection solenoid (SOL1)
Stack top detection sensor-1 (S1)
Stack top detection sensor-2 (S2
Movable tray lower limit sensor (S14)
Probable cause
Movable tray shift motor (M1)
abnormality
Movable tray lower limit sensor (S14)
abnormality
Faulty cables and connectors
Finisher control PC board (FIN)
abnormality
Stack top detection solenoid (SOL1)
abnormality
Stack top detection sensor-1 (S1)
abnormality
Stack top detection sensor-2 (S2)
abnormality
Faulty cables and connectors
Finisher control PC board (FIN)
abnormality
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Timing of detection
A locking signal is detected after the specified time
tray is moving.
*
A locking signal is not monitored from the start driving the motor until
the specified time has passed.
The stack top position of paper is not detected after the movable tray
shift motor (M1) is driven in the specified time when the movable tray is
moved up.
The lower limit position of the stack top of paper is not detected after
the movable tray shift motor (M1) has been driven in the specified time
during the initial movement of the movable tray.
The turning OFF of the movable tray lower limit sensor (S14) is not
detected when the movable tray is moved from a point where this
sensor is turned ON to one point where this sensor is turned OFF after
the movable tray shift motor (M1) has been driven in the specified time.
Checking and measures
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the moto
Measure the voltage on TP17 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
±
5% when shielded. If the voltage does not fall within the range
mentioned, replace the sensor.
Check if the electrical continuity among the connector terminals
is normal. If electricity is not conducted, replace the connectors.
(Finisher control PC board (FIN): CN4, CN10)
If the error still occurs after replacing the motor, sensors and
connectors, exchange the finisher control PC board (FIN).
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the solenoid.
Measure the voltage on TP11 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
±
5% when shielded. If the voltage does not fall within the range
mentioned, replace the sensor.
Measure the voltage on TP20 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
±
5% when shielded. If the voltage does not fall within the range
mentioned, replace the sensor.
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connector. (Finisher control PC board (FIN): CN3)
If the error still occurs after replacing the solenoid, sensors and
connector, exchange the finisher control PC board (FIN).