[F600] F/W update error
Classification
Other service call
Check item
Setting
[F700] Overwrite error
Classification
Other service call
Check item
Setting
[F800] Date error
Classification
Other service call
Check item
Setting
[F900] Model information error
Classification
Other service call
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
The firmware fails to be updated.
1. Perform [3] + [C] + [POWER] → [1] → [START] for "Clear
Error Flag in Software Installation".
2. Reinstall the firmware in error displayed on the F600 error
screen.
Overwriting fails.
If a service call occurs again after the reboot, replace the HDD.
The year 2038 problem
Reset the date, and request the administrator to set the date
and time.
1. Turn the power on while pressing the [6] and [CLEAR]
button.
2. Select [2] key, and then press the [START] button.
3. Press the [START] button on the confirmation screen
displayed. (The date is set to January 1st, 2011.)
4. Request the administrator to set the date and time.
Machine information alignment error. The machine
information is damaged.