Download Print this page

Details Of The Signals - Toshiba e-STUDIO 2555C Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

13.2.2

Details of the signals

1. CTRON signal (output signals)
These signals are synchronized with electronic counter of the equipment and they become "Low"
when one sheet of paper is counted up. They are the signals for coin controller, and output from the
LGC board.
<CTRON KCTRON>
Single count
2. CTRCNT signal (input signals)
The CTRCNT signal enables to accept copies when the coin controller is connected, and copies can
be accepted with "Low". In case of "High", "Set Key Counter" appears and copies cannot be made.
3. MCRUN signal (output signal)
The MCRUN signal is changed to "Low" during copying. It becomes "Low" at 30 ms or more before
the CTRON signal is turned ON, and "High" at 50 ms or more after the EXTCTR signal goes OFF.
However, if copying is interrupted due to forced toner supply or similar, this signal is "High" until
copying is made possible again. This is the signal for the coin controller.
<MCRUN>
OFF
ON
<CTRON>
OFF
ON
<EXTCTR>
OFF
ON
4. EXTCTR signal (output signal)
The EXTCTR signal is synchronized with "Exit sensor ON" and becomes "Low" (ON) for 200 ms.
The coin controller counts the number of times with this signal.
This is the signal only for the coin controller.
<PIS-EXIT: Paper exit sensor>
With paper
Without paper
<EXTCTR>
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
OFF
ON
Fixed time
Fig.13-1
Fixed time
Fig.13-2
(Paper length / Feeding speed)
OFF
ON
Fig.13-3
13 - 3
Fixed time
Fixed time
e-STUDIO2555C/3055C/3555C/4555C/5055C
EXTERNAL COUNTERS
13