6.1.8

Image dimensional adjustment at the scanning section

[A] Image distortion
A
Step 1
C
Step 2
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Press [FAX] to make a copy of any image on a sheet of A3/LD paper.
(3)
Key in [3033] and press the [START] button to move the carriage to the adjustment position.
(4)
Make an adjustment in the order of step 1 and 2.
Step 1
In case of A:
Tighten the mirror-3 adjustment screw (Rear) [1]
(CW).
In case of B:
Loosen the mirror-3 adjustment screw (Rear) [1]
(CCW).
e-STUDIO2555C/3055C/3555C/4555C/5055C
SETTING / ADJUSTMENT
Feeding direction
Feeding direction
Fig.6-13
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
6 - 18
B
D
Fig.6-14