[C970] High-voltage transformer abnormality
Classification
Copy Process related service call
Check Item
Main charger
Spring of high-voltage supply
contact point
Needle electrode
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
High-voltage transformer abnormality: Leakage of the main
charger is detected.
Check if the main charger is installed securely.
Check if the spring of high-voltage supply contact point is
deformed.
Check if the needle electrode is broken or the main charger
grid is deformed.
Check if any foreign matter is on the needle electrode or
main charger grid.