12.2.4

Procedure for disabling data encryption function

The basic procedure is the same as the one for enabling this function. To disable it, set "0 (Invalid)" in
the code 08-9379 at step  P. 12-9 "[D] Enable data encryption function".
12.2.5
Procedure for discarding HDD when data encryption function is
enabled
Set the data encryption function disabled following the procedure shown in  P. 12-11 "12.2.4
Procedure for disabling data encryption function". Then perform the code 3C->6 : Erase HDD Securely
(HDD securely erasing) to completely erase the data in the HDD.