Poor Cleaning - Toshiba e-STUDIO 2555C Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

8.5.25

Poor cleaning

Notes:
Poor cleaning may occur in feeding direction.
Cause/Section
Step
Developer
1
material
Drum cleaner
2
3
Transfer belt
4
cleaner
5
6
Toner
7
recovery
auger
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Fig.8-30
Check item
Is the specified developer material
used?
Is there dust on the drum cleaning
blade edge?
Is the drum cleaning blade peeled?
Is there paper dust on the edge of
transfer belt cleaning blade?
Is the transfer belt cleaning blade
peeled?
Is the transfer belt cleaning blade in
proper contact with the transfer belt?
Is the toner recovery defective?
8 - 317
Measures
Use the specified developer material
and toner.
Clean or replace it.
Replace the blade.
Clean or replace it.
Replace the blade.
Take off the transfer belt and check if
the transfer belt cleaning blade
pressure spring and the pressure
hook are installed properly.
Clean the toner recovery auger.
Check the cleaning blade pressure.