Blurred Image - Toshiba e-STUDIO 2555C Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

8.5.8

Blurred image

Cause/Section
Step
Scanner
1
Drum
2
Ozone
3
exhaust
4
LED head
5
Main charger
6
Main charger
7
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
Fig.8-12
Check item
Is the scanner bedewed?
Is the drum bedewed or dirty?
Is the ozone exhaust fan operating
properly?
Is the ozone filter stained or
damaged?
Is there foreign matter or dust on the
LED head?
Is the charger grid dirty or deformed? Clean or replace the charger grid.
Is there foreign matter on the
charger grid?
8 - 290
Measures
Clean it.
Wipe the drum with dry cloth.
* Be sure never use alcohol or
other organic solvents because
they have bad effect on the drum.
Check the connection of the
connector.
Replace it.
Clean the LED head.
Remove foreign matter.
Clean or replace the charger grid.