Download Print this page

Toshiba e-STUDIO 2555C Service Manual page 1060

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

Sub
05/08
Mode
Element
element
05
Adjustmen
Process
Developm
Auto adj. for dev.
t mode
ent
material supply and
ATS
05
Adjustmen
Process
Developm
Auto adj. for dev.
t mode
ent
material supply and
ATS
05
Adjustmen
Process
Developm
Auto adj. for dev.
t mode
ent
material supply and
ATS
05
Adjustmen
Process
Developm
Auto adj. for dev.
t mode
ent
material supply and
ATS
05
Adjustmen
Process
Developm
Auto adj. for dev.
t mode
ent
material supply and
ATS
05
Adjustmen
Process
Developm
Adjustment of auto-
t mode
ent
toner initial
adjustment reference
setting value (YMCK)
05
Adjustmen
Process
Developm
Adjustment of auto-
t mode
ent
toner initial
adjustment reference
setting value (YMCK)
Item
Subitem
Code
2400
2401
2402
2403
2404
2405
2405
Sub-
Default
Acceptable
Details
code
value
value
Adjustment for All
-
0-255
(Y,M,C,K)
Adjustment for Y
-
0-255
Adjustment for M
-
0-255
Adjustment for C
-
0-255
Adjustment for K
-
0-255
0
Adjustment of
Refer to
0-255
(YMCK) Y
content
s
1
Adjustment of
Refer to
0-255
(YMCK) M
content
s
1
RAM
Contents
M
The value starts changing approx. 3 minutes after this
adjustment is started. The value is automatically set
during this adjustment (approx. 2 minutes).
(As the value increases, the sensor output increases
correspondingly.)
M
The value starts changing approx. 3 minutes after this
adjustment is started. The value is automatically set
during this adjustment (approx. 2 minutes).
(As the value increases, the sensor output increases
correspondingly.)
M
The value starts changing approx. 3 minutes after this
adjustment is started. The value is automatically set
during this adjustment (approx. 2 minutes).
(As the value increases, the sensor output increases
correspondingly.)
M
The value starts changing approx. 3 minutes after this
adjustment is started. The value is automatically set
during this adjustment (approx. 2 minutes).
(As the value increases, the sensor output increases
correspondingly.)
M
The value starts changing approx. 3 minutes after this
adjustment is started. The value is automatically set
during this adjustment (approx. 2 minutes).
(As the value increases, the sensor output increases
correspondingly.)
M
<Default value>
25/30/35ppm: 130
45/50ppm: 140
M
<Default value>
25/30/35ppm: 130
45/50ppm: 140
Proce
Servic
dure
e UI
5
Yes
5
Yes
5
Yes
5
Yes
5
Yes
4
Yes
4
Yes

Hide quick links:

Advertisement

loading