[Procedure to key in adjustment values]
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification. By pressing the [FAX] button,
immediately after starting the Adjustment Mode (05), single-sided test copying can be performed
(normal copy mode).
<Operation keys>
0
5
POWER
1
: Key in codes.
Digital keys
START
Digital keys
: Key in adjustment
values.
( CLEAR Use to make corrections)
Value ZZZ is stored
OK
replacing values YYY.
or
INTERRUPT
FAX
Test copy
START
If the test copy does not
satisfy the specified values,
return to step 1 and
repeat the adjustment
procedure.
Power OFF/ON : Exit the Adjustment Mode.