Figure 2-18 Pft Connector Pin Assignment - NEC NEAX2000 IVS2 Manual

Integrated voice server, remote pim system
Hide thumbs Also See for NEAX2000 IVS2:
Table of Contents

Advertisement

CHAPTER 2 INSTALLATION
Installation for Remote Site
(3) Connect the 25-pair cables on the MDF.
Figure 2-18
shows the PFT connector pin assignment for each PFT circuit number
(No. 0-No. 7).
1
2
3
4
5
6
7
8
9
10 8LC. R2
11 C.O. R2
12 8COT. R2 37 8COT. T2
13 Sta. R3
14 8LC. R3
15 C.O. R3
16 8COT. R3 41 8COT. T3
17 Sta. R4
18 8LC. R4
19 C.O. R4
20 8COT. R4 45 8COT. T4
21 Sta. R5
22 8LC. R5
23 C.O. R5
24 8COT. R5 49 8COT. T5
25
Page 44

Figure 2-18 PFT Connector Pin Assignment

PFT0
Sta. R0
26 Sta. T0
8LC. R0
27 8LC. T0
No. 0
C.O. R0
28 C.O. T0
8COT. R0 29 8COT. T0
Sta. R1
30 Sta. T1
8LC. R1
31 8LC. T1
No. 1
C.O. R1
32 C.O. T1
8COT. R1 33 8COT. T1
Sta. R2
34 Sta. T2
35 8LC. T2
No. 2
36 C.O. T2
38 Sta. T3
39 8LC. T3
No. 3
40 C.O. T3
42 Sta. T4
43 8LC. T4
No. 4
44 C.O. T4
46 Sta. T5
47 8LC. T5
No. 5
48 C.O. T5
50
PFT1
1
Sta. R6
26 Sta. T6
2
8LC. R6
27 8LC. T6
3
C.O. R6
28 C.O. T6
4
8COT. R6 29 8COT. T6
5
Sta. R7
30 Sta. T7
6
8LC. R7
31 8LC. T7
7
C.O. R7
32 C.O. T7
8
8COT. R7 33 8COT. T7
9
34
10
35
11
36
12
37
13
38
14
39
15
40
16
41
17
42
18
43
19
44
20
45
21
46
22
47
23
48
24
49 E
25
50 –27 V
2
NEAX2000 IVS
Remote PIM System Manual
No. 6
No. 7
ND-70917 (E), Issue 1.0