LH79524/LH79525 User's Guide
11.2.2.23 Resistor Configuration Control 17 Register (RESCTL17)
The RESCTL17 Register allows software to configure a number of the LH79524/LH79525
pull-up/pull-down resistors.
BIT
FIELD
RESET
RW
BIT
FIELD
RESET
RW
ADDR
Table 11-46. RESCTL17 Register
31
30
29
28
27
0
0
0
0
0
RO
RO
RO
RO
RO
15
14
13
12
11
0
0
0
0
0
RO
RO
RO
RO
RO
Table 11-47. RESCTL17 Fields
BIT
NAME
31:2
///
Reserved Reading returns 0. Write the reset value.
Pin SDCLK Resistor Assignment
00 = No Pull-Down or Pull-Up
1:0
SDCLK
01 = Pull-Down
10 = Pull-Up
11 = Reserved
26
25
24
23
///
0
0
0
0
RO
RO
RO
RO
10
9
8
7
///
0
0
0
0
RO
RO
RO
RO
0xFFFE5000 + 0x84
DESCRIPTION
Version 1.0
I/O Configuration
22
21
20
19
18
0
0
0
0
0
RO
RO
RO
RO
RO
6
5
4
3
2
0
0
0
0
0
RO
RO
RO
RO
RO
17
16
0
0
RO
RO
1
0
SDCLK
0
1
RW
RW
11-33