LH79524/LH79525 User's Guide
BITS
7
6
5
4
3
2
1
0
Table 6-21. INSTATUS Fields (Cont'd)
NAME
Transmit Complete Denotes a frame has been successfully trans-
mitted. This bit is reset to 0 when read.
TXCOMPLETE
1 = Transmit complete
0 = No complete transmit
Transmit Buffers Exhausted In Mid-frame The transmit buffers
have run out of data before the transmission of the frame completed.
This bit is reset to 0 when read.
TXBUFEXH
1 = Transmit buffers exhausted mid-frame
0 = No error
Retry Limit Exceeded The programmed retry limit was exceeded
without a successful transmission. This bit is reset to 0 when read.
RETRYLIM
1 = Retry limit exceeded
0 = No error
Ethernet Transmit Buffer Underrun The transmit DMA did not fetch
frame data in time for it to be transmitted or response returned 'Not OK'.
Also 1 if a Used bit is read mid-frame or when a new Transmit Queue
ETHTXBUFUR
Pointer is written. This bit is reset to 0 when read.
1 = Transmit buffer underrun
0 = No error
Transmit Used Bit Read Indicates that a transmit buffer descriptor
has been read with its Used bit set. This bit is reset to 0 when read.
TXUSDBITRD
1 = 'Used' bit set
0 = No error
Receive Used Bit Read Set when a receive buffer descriptor is read
with its Used bit set. This bit is reset to 0 when read.
RXUSDBITRD
1 = Used bit set
0 = No error
Receive Complete A frame has been stored in memory. This bit is
reset to 0 when read.
RXCOMP
1 = Receive complete
0 = No receive complete
Management Frame Sent The PHY maintenance register has com-
pleted its operation. This bit is reset to 0 when read.
MNGFRMSENT
1 = Management frame sent
0 = No management frame sent
FUNCTION
Version 1.0
Ethernet MAC Controller
6-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lh79525

Table of Contents