Sharp LH79524 User Manual page 411

Table of Contents

Advertisement

Reset, Clock, and Power Controller
13-30
Table 13-47. INTCONFIG Fields
BITS NAME
Configures External Interrupt INT3
00 = Configures INT3 to be a level trigger, active LOW.
7:6
INT3
01 = Configures INT3 to be a level trigger, active HIGH.
10 = Configures INT3 to be a falling-edge trigger.
11 = Configures INT3 to be a rising-edge trigger.
Configures External Interrupt INT2
00 = Configures INT2 to be a level trigger, active LOW.
5:4
INT2
01 = Configures INT2 to be a level trigger, active HIGH.
10 = Configures INT2 to be a falling-edge trigger.
11 = Configures INT2 to be a rising-edge trigger.
Configures External Interrupt INT1
00 = Configures INT1 to be a level trigger, active LOW.
3:2
INT1
01 = Configures INT1 to be a level trigger, active HIGH.
10 = Configures INT1 to be a falling-edge trigger.
11 = Configures INT1 to be a rising-edge trigger.
Configures External Interrupt INT0
00 = Configures INT0 to be a level trigger, active LOW.
1:0
INT0
01 = Configures INT0 to be a level trigger, active HIGH.
10 = Configures INT0 to be a falling-edge trigger.
11 = Configures INT0 to be a rising-edge trigger.