Verifying AC Power

AC Power Troubleshooting Reference
Applicable Parts
Power Cord
AC Accessory Panel
Wall Outlet
AC Power Troubleshooting Procedure
Step
Actions and Questions
1
For 115 V:
1. Disconnect the AC power cord from the wall
outlet.
AC Neutral
2. Measure the AC voltage between AC Line and
Neutral, between AC Line and Ground, and
between AC Neutral and Ground.
3. The voltage between Line and Neutral and
between Line and Ground should range from 99
to 135 VAC and the voltage between Neutral and
Ground should be less than 3 VAC.
Is the AC voltage within specification?
For 220V:
1. Disconnect the AC power cord from the wall
outlet.
Neutral
2. Measure the AC voltage between Line and
Neutral, between AC Line and Earth/Ground,
and between Neutral and Earth/Ground.
3. The voltage between Line and Neutral and
between Line and Earth/Ground should range
from 198 to 254 VAC and the voltage between
Neutral and Ground should be less than 3 VAC.
Is the AC line voltage within specification?
4-8
References
Print Engine Electrical Specifications (page 1-13)
AC Accessory Panel Plug/Jack Locator (page 10-15)
PL8.1 Print Engine Electrical (page 9-40)
Earth/GND
Line
Neutral
Yes
Go to Step 2.
AC Line
s4400-285
Go to Step 2.
Earth/GND
Line
s4400-286
Phaser 5500 Printer Service Manual
No
Inform
customer of
insufficient
voltage or
improper
wiring.
Inform
customer of
insufficient
voltage or
improper
wiring.