Jam at G (Buffer Path Sensor Static) Troubleshooting Procedure (Continued)
Step
Actions and Questions
8
Check for +5 V to the Buffer Path Sensor.
Is there +5 V across J8302A-15 <=>
J8302A-13 on the Finisher Main PWB?
9
Check Buffer Path Sensor signal.
Does the voltage across P8302A-14 <=>
P8302A-13 on the Finisher Main PWB
change when the actuator is operated?
10
Test the Registration Motor.
Run the Service Diagnostics Finisher
Registration Motor Test.
Does the motor rotate normally?
11
Test the Buffer Roller Drive.
Run the Service Diagnostics Finisher
Registration Motor CCW test.
Does the Buffer Roller rotate?
12
Print a Test Print.
Does the error still occur?
13
Check Main Drive harness connections.
Are P/J8335 and P/J8304 connected?
14
Print a Test Print.
Does the error still occur?
15
Check Main Drive Harness continuity.
1. Disconnect P/J8335 and P/J8304.
2. Check for continuity at the following:
P/J8335-1 <=> P/J8304-7
P/J8335-2 <=> P/J8304-8
P/J8335-3 <=> P/J8304-9
P/J8335-4 <=> P/J8304-11
P/J8335-5 <=> P/J8304-10
P/J8335-6 <=> P/J8304-13
Are these conductive?
16
Check Registration Motor resistance.
Is there some amount of resistance
across P8335-2/5(COM) and P8335-1/3/
4/6?
17
Check for +24 V to the Registration Motor.
Is there +24 V across J8304-8 <=>
ground and J8304-10 <=> ground on the
Finisher Main PWB?
18
Replace the Registration Motor.
Print a Test Print.
Does the error still occur?
3-108
Yes
Go to Step 9.
Replace the
Finisher Main
PWB
(page 3-248).
Replace the
Finisher Main
PWB
(page 3-248).
Go to Step 13.
Go to Step 13.
Go to Step 15.
Go to Step 15.
Go to Step 16.
Go to Step 17.
Go to Step 18.
Replace the
Finisher Main
PWB
(page 3-248).
Phaser 5500 Printer Service Manual
No
Replace the
Finisher Main
PWB
(page 3-248).
Replace the
Buffer Path
Sensor
(page 3-207).
Go to Step 11.
Restore operation
and go to
Step 12.
Problem solved.
Connect and go
to Step 14.
Problem solved.
Repair the Main
Drive Harness.
Replace the
Registration
Motor
(page 3-245).
Replace the
Finisher Main
PWB
(page 3-248).
Problem solved.