Drum Cartridge Failure - J4-1 Atc Snr Defect; Replace Drum Cartridge - J6-1 Drum End Of Life - Fuji Xerox Phaser 5500 Service Manual

Table of Contents

Advertisement

Drum Cartridge Failure - J4-1 ATC SNR Defect

The ATC Sensor is defective.
Applicable Error Code
Drum Cartridge Failure - J4-1 ATC SNR Defect
Drum Cartridge Failure (ATC Sensor) Troubleshooting Reference
Applicable Parts
Drum Cartridge
Front Harness A
Drum Cartridge
Detect Switch
Engine Logic Board
Drum Cartridge Failure (ATC Sensor) Troubleshooting Procedure
Step
Actions and Questions
1
Replace the Drum Cartridge.
Does the error reoccur?
2
Test the Front Harness A.
Run the Service Diagnostics DRUM
Cartridge Detect Switch test.
Does the switch status change when
the Drum Cartridge is moved in and
out?
3
Check the DRUM Cartridge Detect Switch
connection.
Is P/J404 connected?
4
Check DRUM Cartridge Detect Switch
continuity.
Is there continuity between P/J404-1
<=> P/J404-3 when the Drum Cartridge
is installed?
5
Check for +5 V to the DRUM Cartridge
Detect Switch.
Is there +5 V across P/J404-3 (+) <=>
ground?

Replace Drum Cartridge - J6-1 DRUM End of Life

The Drum Cartridge has reached its end of life count.
3-200
References
Print Engine P/J Drum and Toner (page 10-6)
Print Engine P/J Engine Logic Board (page 10-13)
Print Engine LVPS Wiring (page 10-21)
Print Engine Drive/CRUM Wiring (page 10-25)
PL5.1 Laser, CRU and Toner Dispense (page 9-32)
PL8.1 Print Engine Electrical (page 9-40)
Phaser 5500 Printer Service Manual
Yes
Go to Step 2.
Replace the
Engine Logic
Board
(page 8-89).
Go to Step 4.
Go to Step 5.
Replace the Drum
Cartridge Detect
Switch
(page 8-60).
No
Problem solved.
Go to Step 3.
Connect P/J404.
Repair the wiring.
Replace the
Engine Logic
Board
(page 8-89).