Exit Pwb - Fuji Xerox Phaser 5500 Service Manual

Table of Contents

Advertisement

Exit PWB

1.
Remove the Top Cover (page 8-7).
PL8.1.4
Connectors
Exit PWB
2.
Disconnect all connectors from the Exit PWB. Connector P/J403 has a hook.
Disconnect it by pushing the hook.
3.
Remove the two screws securing the Lower Bracket to the frame.
4.
Release the locks of the supports holding the Exit PWB to the frame as shown in
the figure.
5.
Remove the Exit PWB together with Lower Bracket from the frame.
6.
Remove the two screws securing the Exit PWB to the Lower Bracket.
7.
Remove the Exit PWB.
Replacement Note
Fit the tips of the supports into the holes on the Exit PWB.
8-88
Supports
Lower Bracket
Phaser 5500 Printer Service Manual