Remote Site C Configuration

Command
disconnect a
set a:1:all type data
set a:2:all type data
disconnect 6
set 6:1:all type data
connect a:1:11-14 a:2:1-4
connect a:1:16-19 6:1:1-4
connect a:1:21-24 6:2:1-4
set ipds0 assign a:1:15
set ipds0 ip address
192.168.1.103 255.255.255.0
set ipds0 up
set ipds0 navalarm off
set snmp nms 1 192.168.0.254 Set up SNMP Trap address for the Compact T1

Test

After configuring all the Compact T1, verify connectivity to the NMS from each Unit.
> Ping 192.168.0.254
Response should be:
>192.168.0.254 is reachable
Compact T1 - Release 6.1
Setup of DS0 Management Channel
Description
Disconnects all connections to slot a (controller)
Sets all DS0s on T1-1 to data signaling type
Sets all DS0s on T1-2 to data signaling type
Disconnects the router in slot 6
Sets all DS0s on slot 6 to data signaling type
Connect channels to cell site C
Connect channels to cell site D1
Connect channels to cell site D2
Assign channel to IPDS0 management channel
Configure IPDS0 ip address
Enable IPDS0
Suppress IPDS0 alarm
Configuration