Black Box Compact T1 MT850A User Manual page 162

Multi-service delivery terminal
Table of Contents

Advertisement

CLI Commands
set
payload
threshold
5-78
on
Enable detection
off
Disable detection
Apply a payload loopback to the DS1 interface. If the payload
command is not used, the default for payload loopback is loopdown.
loopdown
Disable the payload loopback
loopup
Enable the payload loopback
Set defect thresholds for a DS1. Defaults for all are 0.
day
Set threshold for a daily interval
bes
Bursty errored seconds range: 0 - 86400
css
Controlled slip seconds range: 0 - 86400
dm
Degraded minutes range: 0 - 1440
es
Errored seconds range: 0 - 86400
lcv
Line code violations range: 0 - 133401600
les
Line errored seconds range: 0 - 86400
pcv
Path code violations range: 0 - 133401600
sefs
Severely errored frame seconds range: 0 - 86400
ses
Severely errored seconds range: 0 - 86400
U
uas
navailable seconds range: 0 - 86400
min15
Set threshold for a 15 minute interval
bes
Bursty errored seconds range: 0 - 900
css
Controlled slip seconds range: 0 - 900
dm
Degraded minutes range: 0 - 15
es
Errored seconds range: 0 - 900
lcv
Line code violations range: 0 - 1389600
les
Line errored seconds range: 0 - 900
pcv
Path code violations range: 0 - 1389600
sefs
Severely errored frame seconds range: 0 - 900
ses
Severely errored seconds range: 0 - 900
U
uas
navailable seconds range: 0 - 900
Compact T1 - Release 6.1