Black Box Compact T1 MT850A User Manual page 161

Multi-service delivery terminal
Table of Contents

Advertisement

framing
id
lbo
line
linecode
loopdetect
Compact T1 - Release 6.1
Set the DS1 framing type to one of the following:
d4
To D4 Superframe (SF) framing
esf
To Extended Superframe (ESF) framing
tr8afdl
TR-08 A shelf framing with FDL
tr8anofdl
TR-08 A shelf framing with no FDL
tr8b
TR-08 B shelf framing
Set the DS1 circuit identification string. This is the same as dsx1Circuit
Identifier from DS1 MIB transmission vendor's identification. String
text must be enclosed in quotes
Example: set {ds1-addr} id {"string"}
Set the Line Build Out (LBO) to one of the following:
1
DSX-1 equalization for 0-133 feet (equivalent to CSU
attenuation for LBO of 0dB)
2
DSX-1 equalization for 133-266 feet
3
DSX-1 equalization for 266-399 feet
4
DSX-1 equalization for 399-533 feet
5
DSX-1 equalization for 533-655 feet
6
CSU attenuation for LBO of -7.5dB
7
CSU attenuation for LBO of -15dB
8
CSU attenuation for LBO of -22.5dB
Turn a line loopback to the DS1 interface on or off. If the line command
is not used, the default for line loopback is loopdown.
loopdown
Disable the line loopback
loopup
Enable a DS1 line loopback toward the DS1 drop
Set the DS1 interface line coding to one of the following. If the linecode
command is not used, the default for linecode is B8ZS.
ami
Alternate Mark Inversion line coding
b8zs
Binary 8 Zero Substitution line coding.
Enable detection of CSU loop code (10000 for loopup; 100 for
loopdown)
CLI Commands
.
set
5-77

Advertisement

Table of Contents
loading

Table of Contents