Set Alarms; Set Autoexit - Black Box Compact T1 MT850A User Manual

Multi-service delivery terminal
Table of Contents

Advertisement

CLI Commands
set

set alarms

Use the set alarms command to manually set an alarm state for testing.
Syntax:
Example:
{ciritical|major|minor}
critical
major
minor
{off|on}
off
on

set autoexit

Use the set autoexit to set the autoexit feature.
Syntax:
Example:
{off|on}
off
on
5-70
set alarms {critical|major|minor} {off|on}
set alarms critical on
The example set the alarm state of critical on.
Sets a critical alarm
Sets a major alarm.
Sets a minor alarm.
Disables the alarm state.
Enable the alarm state.
set autoexit {off|on}
set autoexit on
The example will enable the auto-exit feature.
Turn off the automatic logout option.
Enable the automatic exit option. Users will be automatically logged off
after 20 minutes of inactivity.