Fxs Signaling Performance - Black Box Compact T1 MT850A User Manual

Multi-service delivery terminal
Table of Contents

Advertisement

FXS Signaling Performance

l
DC Loop Range: 1000
l
Loop Feed: Nominal -48 VDC with 31mA current limit for long loops, -36 VDC
@ 27mA for short loops with automatic battery switching
l
Off-Hook Detection: Detects tip or ring currents > 6mA
l
Ring Ground: Detects ring ground currents > 8mA
l
Ringing Voltage: All-channel simultaneous ringing power, 85 V rms, 20 Hz
l
Maximum Ringers: 5 REN, FCC Class B ringers
l
Internal Ringing Cadence: Ringing cadence is 2 seconds on, 4 seconds off for
E&M wink start conversion modes
l
Control Technique: Solid-state with no mechanical relays
l
Overvoltage: UL 1950, FCC Part 68 lightning protection
l
Overcurrent: 600 V rms, 60 Amps
l
Supports CLASS features such as calling party ID, three-way calling, and
distinctive ringing
l
Calling Party Disconnect: Calling party (forward) disconnect provides 2 second
current interruption to disconnect answering devices and modems - requires
E&M signaling service on the T1
l
FXS Signaling: FXS loop start or FXS ground start with LS/GS selection per
channel
l
FXSDN Signaling: E&M immediate or wink start to either loop start or ground
start conversion with ringback tone for carrier services such as Megacom
Flexpath
number services
l
Ringer Equivalency Number (REN): 0.0 by definition
Compact T1 - Release 6.1
standard, 1600
®
®
®
, DSS
, VPN
, VNET
extended
®
, etc. Wink delay for advanced ANI/DNIS 800
FXS Voice Card
Technical Specifications
®
,
8-5

Advertisement

Table of Contents