Set Up The Ocu-Dp Card - Black Box Compact T1 MT850A User Manual

Multi-service delivery terminal
Table of Contents

Advertisement

Set Up the OCU-DP Card

The following is a basic setup for the OCU-DP card.
Command
set {ocudp-addr} baud
{2400|4800|9600|19200|38400|
56000*|64000}
set {ocudp-addr} up
show {ocudp_card-addr}
disconnect a
set {ds0-addr} type data
connect {ds0-addr}
{ocudp-addr}
show connect
(ocudp_card-addr}
Compact T1 - Release 6.1
Description
Set the OCU-DP Baud rate.
Where ocudp-addr = {slot:port} of the
OCU-DP card to apply settings to
Set the OCU-DP port 1 up
Show the OCU-DP card settings.
Where ocudp_card-addr = {slot} of the
OCU-DP card
Disconnects all connections to slot a
(controller)
Sets a DS0 data signaling type
Connects DS0 (in previous step) to OCU-DP
port (in previous step)
Displays connect information for OCU-DP
card
Configuration
Basic System Setup
4-9