Clear Alarm - Black Box Compact T1 MT850A User Manual

Multi-service delivery terminal
Table of Contents

Advertisement

Diagnostices & Troubleshooting
Alarms
Display Alarms
Use the alarms command to display the active alarms. Each alarm is related to a
particular address and has a severity category (major, minor, critical, alert). The
report can be filtered by port address and/or severity.
Syntax:
> alarms
Time
07:35:45 01/04/2002 Major
07:35:21 01/04/2002 Minor
07:34:57 01/04/2002 Critical Test Critical Alarm
07:30:39 01/04/2002 Major
03:50:55 01/04/2002 Major
00:00:20 01/01/2002 Major
00:00:20 01/01/2002 Major
00:00:05 01/01/2002 Major
00:00:05 01/01/2002 Major
Total=10
Category = bri|ds1|env|equipment|fxo|fxs|rtr|v35
Severity = alert|critical|info|major|minor

Clear Alarm

Once an alarm is identified then the process of clearing it can begin.
l
Silence Alarm, if necessary (Alarm Cut Off CLI command: aco)
l
Check Connection
l
Check Cable, replace if necessary
l
Check hardware and replace if necessary
l
Call Customer Service
B-4
alarms [slot|slot:port|slot:port:channel] [category]
[severity]
Date
Severity Description
Test Major Alarm
Test Minor Alarm
1:1-OCUDP Out of Service
1:1-OCUDP Loss of Signal
4:1-CMG Ethernet Link Down
5:1-RTR Ethernet Link Down
A:2-DS1 Loss Of Signal
A:1-DS1 Loss Of Signal
Compact T1 - Release 6.1

Advertisement

Table of Contents
loading

Table of Contents