CLI Commands
set

set (v54)

Use the set (v54) command to setup V.54 Loopback Test Parameters. The command specifies
the range of channels within that card, and the setting to apply.
Syntax:
Example:
{v54-addr}
In the form of {slot:port}.
slot
port
{setting}
equipment
address
clear
ignoreack
loopdown
loopup
5-204
set {v54-addr} v54 {setting} [off|on] [n] [nnn]
set 6:1 v54 equipment clear
The example will clear the loop test counter on the V.54 card in slot 6, port 1.
Slot number (1 - 6) for service cards.
Port number or range.
Set the V.54 Equipment (Tx) parameters:
Syntax: set {v54-addr} v54 equipment address {nnn}
Set V.54 loop test address [nnn]
Set the address to be tested.
[nnn] {nnn} must be one of the following:
0 - 255.1, 3, 5, 7, 9, 11, 13, 15,17, 19, 21, 23, 25, 27, 29, 31, 37, 39,
43, 45, 47, 51, 53, 55, 59, 61, 63, 85, 87, 91, 95, 111, 119, 127, 255
(255 disables). See chart below.
Syntax: set{v54-addr} v54 equipment clear
Clear the bit error rate counters during BER test
Syntax: set{v54-addr} v54 equipment ignoreack
{off|on}
Ignore V.54 ACK check [off|on]
Ignore acknowledge from remote equipment. This allows potential
testing with non-compliant equipment by ignoring the acknowledge
phase. WARNING: When choosing this option, the V.35 card
will no longer be compliant with the V.54 specification. Use for
debug purposes only.
Syntax: set{v54-addr} v54 equipment loopdown
Stop the test sequence
Syntax: set{v54-addr} v54 equipment loopup
Start the test sequence