If you see code number from E001 to E100 display on the keypad, they are the drive's fault codes.
For more information on these fault codes, see Chapter 14 Fault Codes in the VFD-ED user manual.
Code#
KPC-CC01 Display
F111
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F112
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F113
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F114

Chapter 14 Fault Codes

Fault Name
cF2 EEPROM error
Fault occurs when there is an EEPROM read error
Action and Reset
All parameters return to default settings
N/A
Press the RESET key on the digital keypad
Fault Name
Fault occurs when switching the manual/auto mode to
Floor auto-tuning is not
auto mode without finishing the hoistway floor
finished
auto-tuning
Action and Reset
Stops urgently
Pr.03-00 (Hoistway Auto-tuning)
Switch to the manual mode
Fault Name
Fault occurs when the drive does not respond a ready
Drive is not ready
signal
Action and Reset
Two seconds
N/A
Press the RESET key on the digital keypad, press the external reset device, or
power-on again (choose either)
Fault Name
Fault occurs when BK1 (Brake-1 travel switch) signal is
BK1 is not active
not active after brake contactor activates (ON)