Fault Name
Fault occurs when the difference between the position
Upward forced
and hoistway auto-tuning is larger than Pr.03-16 setting
deceleration 3
value after the third one upward forced deceleration
switch activates during upward running
Action and Reset
Stops urgently
Pr.03-16 (Position Difference Protection)
Resets automatically after five seconds
Fault Name
Fault occurs when neither the first one downward forced
Downward limit action
deceleration switch nor the upper leveling sensor (DZU)
activates after downward limit switch activates
Action and Reset
Stops urgently
MI=34 LSD (Lower limit switch)
Resets automatically when no fault is identified
Fault Name
Fault occurs when the difference between the position
Downward forced
and hoistway auto-tuning is larger than Pr.03-16 setting
deceleration 1
value after the first one downward forced deceleration
switch activates during downward running
Action and Reset
Stops urgently
Pr.03-16 (Position Difference Protection)
Resets automatically after five seconds
Fault Name
Fault occurs when the difference between the position
Downward forced
and hoistway auto-tuning is larger than Pr.03-16 setting
deceleration 2
value after the second one downward forced
deceleration switch activates during downward running
Action and Reset
Stops urgently
Pr.03-16 (Position Difference Protection)
Resets automatically after five seconds
Fault Name
Fault occurs when the difference between the position
Downward forced
and hoistway auto-tuning is larger than Pr.03-16 setting
deceleration 3
value after the third one downward forced deceleration
switch activates during downward running
Action and Reset
Stops urgently
Pr.03-16 (Position Difference Protection)
Resets automatically after five seconds
14-16