Chapter 10 Auto-tuning Process | IED-S
 The installation method for car command boards:
Pr.03-51
Setting
Value
0
Front door 1
1
Front door + disability 1
2
Front and rear door 1
Front and rear door +
3
disability 1
10-6-8 Description of Manual Operation
1.
Manual operation includes inspection operation and emergency operation.
2.
Easy steps in entering cartop or pit:
(1) In automatic mode, press the following buttons simultaneously for more than four seconds:
a. Open and close buttons in the car, and
b. Call buttons at the bottom floor and sub-bottom floor.
Then, open and close buttons flash at the same time.
(2) Walk out of the car, and then the door closes automatically.
(3) If the elevator is at the bottom floor, it automatically moves 2.2 m upward at inspection speed,
and then stops. If the elevator is not at the bottom floor, it automatically moves 2.2 m
downward at inspection speed, and then stops.
(4) After the elevator stops, open the layer door within ten seconds. Otherwise, the elevator
returns to automatic mode.
(5) Then, you can enter the cartop or pit. Note that the cartop or pit mode will be cancelled if the
action is not finished within 50 seconds.
3.
Priority for the manual operation:
INSCP (control panel inspection switch) = TCI (cartop inspection switch) > EIS (emergency
operation) > INSIC (car inspection switch)
Cartop Board
EA-CT01
J5
1
2
Function
64F
32F
32F
16F
Note: Pr.03-51 synchronously enables or disables the corresponding hall calls
J4
3
Car
Command
Board
EA-CP16
4
The Installation Sequence for Car Command Board
1
2
F 1
16F
F 17
32F
F 1
16F
F 17
32F
F 1
16F
F 17
32F
F 1
16F
F+D 1
16F
* F: Front door / B: Rear door / D: Disability
10-22
3
4
F 33
48F
F 49
64F
F+D 1
16F
F+D 17
32F
B 1–16F
B 17
32F
B 1
16F
B+D 1
16F