MI=40 DLS3 (Third one downward forced deceleration)
Pr.03-42 (DLS3 Over-speed Protection)
Resets automatically after 60 seconds
Fault Name
Fault occurs when speed is larger than Pr.03-40 (DLS2
Over-speed Protection) after DLS2 (Second one
DLS2 over-speed
downward forced deceleration) activates during
downward running
Action and Reset
Stops urgently
MI=39 DLS2 (Second one downward forced deceleration)
Pr.03-40 (DLS2 Over-speed Protection)
Resets automatically after 60 seconds
Fault Name
Fault occurs when speed is larger than Pr.03-38 (DLS1
DLS1 over-speed
Over-speed Protection) after DLS1 (First one downward
forced deceleration) activates during downward running
Action and Reset
Stops urgently
MI=38 DLS1 (First one downward forced deceleration)
Pr.03-38 (DLS1 Over-speed Protection)
Resets automatically after 60 seconds
Fault Name
Fault occurs when target floor is larger than highest
Target error 1
floor during upward direct docking running
Action and Reset
Stops urgently
Pr.00-18 (Target Floor), Pr.03-01 (Highest Physical Floor)
Resets automatically after 60 seconds
Fault Name
Fault occurs when target floor is lower than nearest stop
Target error 2
floor during upward direct docking running
Action and Reset
Stops urgently
Pr.00-18 (Target Floor), Pr.00-35 (Nearest Stop Floor)
Resets automatically after 60 seconds