15 Fault Codes and Descriptions
Warning
CE01
Comm. Error 1
Fault Name
Over-current during
acceleration
Fault
(Output current exceeds
ocA
triple rated current during
Oc at accel
acceleration.)
Over-current during
deceleration
Fault
(Output current exceeds
ocd
triple rated current during
Oc at decel
deceleration.)
Over-current during
steady state operation
Fault
(Output current exceeds
ocn
triple rated current during
Oc at normal SPD
constant speed.)
Fault
Hardware failure in
ocS
current detection
Oc at stop
Fault
Ground fault
GFF
Ground fault
Di s p la y e rr o r si g n al
A b b r ev i a te e rr o r c o d e
T h e co d e is d is p l a y e d as s h ow n on K P C- C E 01 .
D i s p la y er r o r d e s c r i p ti o n
Fault Descriptions
Corrective Actions
1. Short-circuit at motor output: Check for possible
poor insulation at the output.
2. Acceleration Time too short: Increase the
Acceleration Time.
3. AC motor drive output power is too small:
Replace the AC motor drive with the next higher
power model.
1. Short-circuit at motor output: Check for possible
poor insulation at the output.
2. Deceleration Time too short: Increase the
Deceleration Time.
3. AC motor drive output power is too small:
Replace the AC motor drive with the next higher
power model.
1. Short-circuit at motor output: Check for possible
poor insulation at the output.
2. Sudden increase in motor loading: Check for
possible motor stall.
3. AC motor drive output power is too small:
Replace the AC motor drive with the next higher
power model.
Return to the factory
When (one of) the output terminal(s) is grounded,
short circuit current is more than 50% of AC motor
drive rated current, the AC motor drive power
module may be damaged.
NOTE: The short circuit protection is provided for
AC motor drive protection, not for protecting the
user.
1. Check the wiring connections between the AC
motor drive and motor for possible short circuits,
also to ground.
2. Check whether the IGBT power module is
damaged.
3. Check for possible poor insulation at the output.