DLS3 Over-speed Protection
Settings
 When elevator runs downward detection, it starts speed detection 0.5 sec. after DLS3 (Third one
downward forced deceleration) activates if there is no DLS4, and starts speed detection once
DLS3 activates if there is DLS4. If the speed detected is larger than Pr.03-42, fault code F199
(DLS3 Over-speed) occurs. The elevator stops urgently and automatically resets after 60
seconds.
ULS4 Over-speed Protection
Settings
 When elevator runs upward detection, it starts speed detection 0.5 sec. after ULS4 (Fourth one
upward forced deceleration) activates. If the speed detected is larger than Pr.03-43, fault code
F197 (ULS4 Over-speed) occurs. The elevator stops urgently and automatically resets after 60
seconds.
DLS4 Over-speed Protection
Settings
 When elevator runs downward detection, it starts speed detection 0.5 sec. after DLS4 (Fourth
one downward forced deceleration) activates. If the speed detected is larger than Pr.03-42, fault
code F198 (DLS4 Over-speed) occurs. The elevator stops urgently and automatically resets after
60 seconds.
Car Call Password
Settings
 When Pr.03-45 (Car Call Password) is not set to 0 (no 0 in the password code), and MI=203
PASSWORD (password car call) is ON, you must press the same value as set in Pr.03-45 for the
car call button on car call board for car call, and then press the desired floor button. At this time,
car call is registered. The car call button at the bottom floor is equal to 1. The interval between
each button pressed should be less than two seconds.
 To modify the car call password, you can choose either:
1. Use built-in keypad or digital keypad KPC-CC01 to modify Pr.03-45 (Car Call Password).
2. Activate MI=204 PASSSET (Execute password setting) first. Then, use car call button settings
on car call board to change or cancel Pr.03-45 (Car Call Password).
 To cancel car call password, press door closing button for five times to set Pr.03-45 (Car Call
Password) to 0.
Four-digit password setting: Press door closing button for one time first, and then use car call
button to set four-digit password.
Five-digit password setting: Use car call button to set.
Floor Display under Inspection
Settings
0–100%
0: No protection
1–100%: percentage of rated speed
0–100%
0: No protection
1–100%: percentage of rated speed
0–100%
0: No protection
1–100%: percentage of rated speed
0–65535
0: No protection
1–100%: percentage of rated speed
0–1
0: Does not display floor when in inspection mode
1: Displays floor when in inspection mode
12-03-9
Chapter 12 Descriptions of Parameter Settings | IED-S
Default: 50
Default: 50
Default: 50
Default: 0
Default: 0