7-1 EMED-PGABD-1*, EMED-PGABD-2
Applicable encoder: A/B/Z & U/V/W Absolute Encoders
* EMED-PGABD-1 has been phased out in the first
quarter of year 2021, and is pin-to-pin replaced by
EMED-PGABD-2 after EOL.
The following table lists the terminal specifications.
Terminal
Vin
TB2
A/O, B/O
GND
AO, /AO, BO, /BO Output signal for the line driver frequency division.
Voltage input, to adjust the amplitude of output voltage at terminal A/O and terminal B/O.
It also provides a 5 V voltage to support line driver's signal.
Vin voltage range: 8–24 V, Max: 24 V.
Output signal for the push-pull voltage frequency division.
Default: Output amplitude is about +24 V. Use SW3 to disable the internal default power.
Required input power through Vin-GND port (i.e. output voltage's amplitude)
Vin voltage range: 8–24 V, Max: 24 V.
Push-Pull Voltage Output
Max. output frequency: 100 kHz
Supports frequency division output, the frequency division range: 1–31.
Common ground terminal connecting to the host controller and the motor drive.
Dimension
Wire Gauge
30–16 AWG 1.6 kg-cm [1.4 Ib-in.]
Descriptions
7-3
Chapter 7 Option Cards | IED-S
Unit: mm [inch]