Chapter 11 Summary of Parameter Settings | IED-S
Pr.
Parameter Name
00-97
IED-S Program Version
00-98
IED-S DateCode
Setting Range
deceleration (ULS1) and leveling sensor are ON
31: Upper limit switch (LSU) is ON
32: Upper limit switch (LSU) is ON
33: Upper limit switch (LSU) is ON for more than 1
second
34: Upper limit switch (LSU) is ON for more than 1.5
seconds
35: Upper limit switch (LSU) is ON for more than 2
seconds
36: Upper limit switch (LSU) is ON for more than 2
seconds
37: Elevator stops at leveling (level) for more than 2
seconds
38: Elevator stops at leveling (level) for more than 2
seconds
39: Hoistway auto-tuning ended
200 (Error): Set Pr.03-00 = 1 when error occurs
201 (Error): Set Pr.03-00 = 1 when Pr.03-01 = 1
(Highest Physical Floor)
202 (Error): Change inspection switch to manual
during hoistway auto-tuning process
203 (Error): Press inspection upward or downward
button during hoistway auto-tuning process
204 (Error): Lower limit switch (LSD) is installed too
low. Lower limit switch (LSD) activates after upper
leveling sensor (DZU) is OFF
205 (Error): Lower limit switch (LSD) is installed too
low. Lower limit switch (LSD) activates after upper
leveling sensor (DZU) is OFF
206 (Error): Lower limit switch (LSD) is ON, first one
downward forced deceleration (DLS1) is not ON
207 (Error): Upper limit switch (LSU) is ON, lower
leveling sensor (DZD) is not ON
208 (Error): Upper limit switch (LSU) is ON, first one
upward forced deceleration (ULS1) is not ON
209 (Error): Error occurs during hoistway auto-tuning
process
210 (Error): Pr.03-00 = 0 during hoistway auto-tuning
process
0.00–655.35
0–65535
11-6