THD (Total Harmonic Distortion)
The table below shows the THDi specification when using Delta's drives (three-phase power models) to
work with AC/DC reactors.
Motor Drive
Spec.
Models without
Reactors in
AC/DC Reactors
Series Spec.
5th
73.3%
7th
52.74%
11th
7.28%
13th
0.4%
THDi
91%
Note
THDi may vary due to different installation conditions and environment (wires, motors).
Note: For three-phase power models, Delta provides 4% DC reactors and 3% AC reactors. Refer to the following
sections to select your applicable reactors.
Installing a DC Reactor
Models without
Built-in DC Reactors
3% Input
5% Input
AC Reactor
AC Reactor
38.5%
30.8%
15.3%
9.4%
7.1%
6.13%
3.75%
3.15%
43.6%
34.33%
THDi Specification
6-9
Chapter 6 Optional Accessories | IED-S
Models with
Built-in DC Reactors
4%
3% Input
DC Reactor
AC Reactor
25.5%
27.01%
18.6%
9.54%
7.14%
4.5%
0.48%
0.22%
38.2%
30.5%
5% Input
AC Reactor
25.5%
8.75%
4.2%
0.17%
28.4%

Advertisement