Chapter 11 Summary of Parameter Settings | IED-S
Pr.
Parameter Name
13-24
Encoder Input Type Settings
13-25
PG Card C+/C-
13-26
Suspension Ratio
13-27
Gear Ratio
13-28
Main Sheave Diameter
13-29
Elevator Rated Speed
13-30
Mechanical Inertia Ratio
Zero Speed at Start-up
13-31
Bandwidth
13-32
Low Speed Bandwidth
13-33
High Speed Bandwidth
Zero Speed at Stop
13-34
Bandwidth
IM Mechanical Brake
13-42
Release Delay Time / PM
Position Control Delay Time
Mechanical Brake Engage
13-43
Delay Time
13-44
Drive Output Delay Time
Operation Contactor Off
13-45
Delay Time
13-48
Voltage of Emergency Power
13-49
EPS Running Frequency
Power Generation Direction
13-51
Search Time
Power Capacity of
13-52
Emergency Power
13-53
STO Latch Selection
13-54
Zero Speed Activation Time
13-55
Zero Speed Stopping Time
Time for Decreasing Torque
13-57
at Stop
13-58
PM Position Control Duration
13-59
PM Position Control Gain (P)
Maximum Current during
13-60
Acceleration
13-61
Forced Deceleration Limit
Setting Range
0–5
0: Disabled
1: Phase A leads in a forward run command and
phase B leads in a reverse run command
2: Phase B leads in a forward run command and
phase A leads in a reverse run command
3: Phase A is a pulse input and phase B is a direction
input. (low input=reverse direction, high input=forward
direction)
4: Phase A is a pulse input and phase B is a direction
input. (low input=forward direction, high input=reverse
direction)
5: Single-phase input
0000h–0001h
0–3
0 = 1: 1
1 = 2: 1
2 = 4: 1
3 = 8: 1
1.00–100.00
100–2000 mm
0.10–4.00 m/s
1–300
1–40 Hz
1–40 Hz
1–40 Hz
1–40 Hz
0.000–2.000 sec.
0.000–2.000 sec.
0.010–0.500 sec.
0.010–1.667 sec.
24.0–375.0 V
DC
48.0–750.0 V
DC
0.00–655.35 Hz
0.0–5.0 sec.
0.0–100.0 kVA
0000h–0007h
0.1–60.0 sec.
0.0–3.0 sec.
0.000–5.000 sec.
0.000–65.535 sec.
0.00–655.00
50–200%
0000h–FFFFh
11-46
Default
1
0000h
1
1.00
400
1.00
20
10
10
10
10
0.250
0.250
0.200
0.200
24.0
48.0
Read only
1.0
0.0
0003h
0.7
0.7
0.000
0.000
80.00
150
0000h