Chapter 6 Optional Accessories | IED-S
Reactor
Model No.
(See Note)
RF008X00A
RF008X00N
RF004X00A
RF004X00N
RF002X00A
RF410X00N
RF300X00A
RF300X00N
Note: 600 V insulated cable wire
Installation
During installation, pass the cable through at least one zero phase reactor. Use a suitable cable type
(insulation class and wire section) so that the cable passes easily through the zero phase reactor. Do not
pass the grounding cable through the zero phase reactor; only pass the motor wire through the zero
phase reactor. With longer motor cables the zero-phase reactor can effectively reduce interference at the
motor output. Install the zero-phase reactor as close to the output of the drive as possible. Diagram A
shows the installation diagram for a single turn zero phase reactor. If the wire diameter allows several
turns, Diagram B shows the installation of a multi-turn zero phase reactor. The more turns, the better the
noise suppression effect.
Diagram A. Single turn wiring diagram for shielding wire with a zero phase reactor
Recommended
Wire Gauge
≤ 8 AWG
≤ 8.37 mm
≤ 4 AWG
≤ 21.15 mm
≤ 2 AWG
≤ 33.62 mm
≤ 300 MCM
≤ 152 mm
Diagram B. Multi-turn zero phase reactor
Wiring
#
Method
Diagram A
2
1
Diagram B
Diagram A
2
1
Diagram B
Diagram A
2
1
Diagram B
Diagram A
2
1
Diagram B
6-36
Applicable Motor Drives
IED022S21A
IED037S21A
IED055S23A
IED075S23A
IED110S23A
IED055S43A
IED075S43A
IED110S43A
IED150S43A
IED185S43A
IED150S23A
IED185S23A
IED220S23A
IED220S43A
IED300S43A
IED370S43A
IED450S43A
IED550S43A
IED750S43A