Settings
VIP Car Call Limit
Settings
 0: When in VIP mode, the method of car call and door open/closing is the same as normal mode.
If elevator has not yet been recalled to VIP floor, VIP mode does not reset to normal mode. If
elevator has been recalled to VIP floor, no matter the floor at which the elevator stops, the VIP
mode is automatically cancelled once there is no car call after door closes.
 1: When elevator is in VIP mode, all car calls are cancelled first. Then, when elevator is recalled
to VIP floor, the elevator door does not close until you press the car call floor button that you
would like to go or press the door closing button. If you release the car call floor button before
door is fully closed, the door opens automatically and no car call can be registered. When
elevator arrives the desired floor, VIP mode is automatically cancelled. When elevator stops at
VIP floor, VIP mode is also automatically cancelled if you do not press the car call floor button that
you would like to go within 30 seconds.
 Common ground of VIP modes:
1. Elevator does not respond to hall calls, and VIP mode is automatically cleared once hall call is
registered (except VIP floor). Elevator responds to car calls only.
2. Once elevator has entered VIP mode, VIP does not return to normal mode until you finish
running the VIP mode according to Pr.03-34 (VIP Cal Call Limit).
 Choose either of the methods to set VIP floor according to Pr.03-33 (VIP Floor) settings:
1. Use MI=164 VIP (VIP mode): When MI=164 is activated, elevator enters VIP mode, is
recalled to the floor specified by Pr.03-33 (VIP Floor), and runs according to Pr.03-34 (VIP
Car Call Limit) settings.
2. Does not use MI=164 VIP (VIP mode): When you press upward or downward hall call button
for the VIP floor, elevator enters VIP mode, is recalled to the floor specified by Pr.03-33 (VIP
Floor), and runs according to Pr.03-34 (VIP Car Call Limit) settings.
 When either Pr.03-35 (HCB J4 Pin1&2 Function) or Pr.03-36 (HCB J4 Pin3&4 Function) is set to
3 (VIP), and the corresponding J4 Pin1&2 or Pin3&4 from hall call board is activated, elevator
enters VIP mode, and uses the floor at which either J4 Pin1&2 or Pin3&4 from hall call board is
activated as VIP floor. Then, elevator is recalled to the VIP floor and runs according to Pr.03-34
(VIP Car Call Limit).
HCB J4 Pin1&2 Function
Settings
HCB J4 Pin3&4 Function
Settings
0: No function
1–64: Set the setting value as the VIP floor of front door
101–164: Set the setting value after minus 100 as the VIP floor of rear door
0–1
0: No function
1: Elevator lock
2: Recall at fire emergency
3: VIP
4: Medical recall
5: Car reader
6: Door open extended button
0: No function
1: Elevator lock
2: Recall at fire emergency
3: VIP
4: Medical recall
5: Car reader
6: Door open extended button
12-03-7
Chapter 12 Descriptions of Parameter Settings | IED-S
Default: 0
Default: 0
Default: 1
Default: 2