Chapter 14 Fault Codes | IED-S
Code#
KPC-CC01 Display
F123
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F124
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F125
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F126
Action
Related Parameters
Reset Method
Fault Name
Fault occurs when FL1NC (Contact B of the relay for
FL1NC ON error
FL1) is not OFF after FL1 (Upper door zone sensor)
activates (ON)
Action and Reset
Stops urgently
MI=3 FL1 (Upper door zone sensor)
MI=5 FL1NC (Contact B of the relay for FL1)
Press the upward or downward operation button for the manual mode, press the
RESET key on the digital keypad, press the external reset device, or power-on
again (choose either)
Fault Name
Fault occurs when FL1NC (Contact B of the relay for
FL1NC OFF error
FL1) is not ON after FL1 (Upper door zone sensor)
deactivates (OFF)
Action and Reset
Stops urgently
MI=3 FL1 (Upper door zone sensor)
MI=5 FL1NC (Contact B of the relay for FL1)
Press the upward or downward operation button for the manual mode, press the
RESET key on the digital keypad, press the external reset device, or power-on
again (choose either)
Fault Name
Fault occurs when FL2NC (Contact B of the relay for
FL2NC ON error
FL2) is not OFF after FL2 (Lower door zone sensor)
activates (ON)
Action and Reset
Stops urgently
MI=4 FL2 (Lower door zone sensor)
MI=6 FL2NC (Contact B of the relay for FL2)
Press the upward or downward operation button for the manual mode, press the
RESET key on the digital keypad, press the external reset device, or power-on
again (choose either)
Fault Name
Fault occurs when FL2NC (Contact B of the relay for
FL2NC OFF error
FL1) is not ON after FL2 (Lower door zone sensor)
deactivates (OFF)
Action and Reset
Stops urgently
MI=4 FL2 (Lower door zone sensor)
MI=6 FL2NC (Contact B of the relay for FL2)
Press the upward or downward operation button for the manual mode, press the
RESET key on the digital keypad, press the external reset device, or power-on
again (choose either)
14-4
Description
Description
Description
Description

Advertisement

Table of Contents
loading

Table of Contents