Setting
MI Function
Value
IICUP (Car inspection upward and
154
attendant direction change)
IICDN (Car inspection downward and
155
attendant direct landing)
156
CARD (Car reader)
CFNLT (Car fan and lighting control
157
switch)
158
ESS (Stop at each floor)
159
FUP (Manual upward fine-tune button)
FDN (Manual downward fine-tune
160
button)
161
ISS (Independent operation switch)
162
IND (Goods only switch)
163
ATS (Attendant mode)
164
VIP (VIP mode)
165
CLIS (Car lighting switch)
166
FS (Car fan switch)
167
DCB2 (Rear door close button)
168
DOB2 (Rear door open button)
DOBH2 (Rear door open extended
169
button)
DCB1B (Front door close auxiliary
170
button)
DOB1B (Front door open auxiliary
171
button)
DOBH1B (Front door open auxiliary
172
extended button)
DCB2B (Rear door close auxiliary
173
button)
174
DOB2B (Rear door open auxiliary
Chapter 12 Descriptions of Parameter Settings | IED-S
ON; under automatic mode when LED indicator is
OFF. Car inspection mode has the lowest priority for
inspection mode (lower than emergency operation).
When LED indicator is ON:
Executes inspection upward operation while in car
inspection mode.
Forces to change the elevator running direction
while in attendant mode.
When LED indicator is ON:
Executes inspection downward operation while in
car inspection mode.
Makes elevator stop at registered car call only, and
does not respond to hall call. But hall call remains
registered and cannot be cancelled while in
attendant mode.
Car call can be registered only when LED indicator
is ON.
Fan stops and lighting is off when LED indicator is
ON.
Executes stop at each floor for car call when LED
indicator is ON. For example, if the elevator stops at
1F, and there is a car call from 5F, it will stop at each
floor–2F, 3F, and 4F–before arriving at 5F.
When LED indicator is ON and door open extended
button is activated, elevator is forced to run upward
manually at fine-tuned speed under automatic
mode, and runs with Pr.04-05 (Leveling Speed)..
When LED indicator is ON and door open extended
button is activated, elevator is forced to run
downward manually at fine-tuned speed under
automatic mode, and runs with Pr.04-05 (Leveling
Speed).
The elevator runs in normal mode independently
instead of parallel control when LED indicator is ON.
Enters goods carrying mode when LED indicator is
ON.
An attendant is accompanied in the elevator to
control upward or downward running and make
elevator stop at designated floor as per passenger
needs.
Car lighting equipment is off when LED indicator is
ON.
Car fan stops when LED indicator is ON.
Rear door close button is pressed when LED
indicator is ON.
Rear door open button is pressed when LED
indicator is ON.
Rear door open extended button is pressed when
LED indicator is ON.
Front door close auxiliary button is pressed when
LED indicator is ON.
Front door open auxiliary button is pressed when
LED indicator is ON.
Front door open auxiliary extended button is
pressed when LED indicator is ON.
Rear door close auxiliary button is press when LED
indicator is ON.
Rear door open auxiliary button is pressed when
12-06-7