8-3 General Specifications
Control Method
Starting Torque
Speed Control Range
Speed Control Accuracy
Speed Response Ability
Max. Output Frequency
Frequency Setting Resolution
Torque Limit
Acceleration / Deceleration
Brake Torque
Motor Protection
Over-current Protection
Ground Leakage Current
Protection
Overload Capacity
Voltage Protection
Over-voltage Protection for
Input Power
Overheating Protection
Protection Level
Operating Temperature
Storage Temperature
Humidity
Vibration
Cooling System
Installation Altitude
Certifications
FOC+PG, FOC+PM
150% at 0 Hz
1: 1000
 0.02%
30 Hz
0.00–400.00 Hz
Digital command: 0.01 Hz; 0.01 m/s
200% of the torque current is the maximum
2
0.10–1.50 m/s
About 125% while ED is 30% (use optional brake resistor)
NOTE: ED is "Executive Duty"
Electronic thermal relay protection
250% of the drive's rated current
More than 50% of the drive's rated current
Endures 60 seconds for 150% of the rated output current;
Endures 10 seconds for 180% of the rated output current
Over-voltage level:
[230V Model] V
> 400V
DC
[460V Model] V
> 800V
DC
Low-voltage level:
[230V Model] V
< 200V
DC
[460V Model] V
< 400V
DC
Varistor (MOV)
Built-in temperature sensor
IP00
-10–40°C, up to 50°C with derating for the operating temperature
-20–60°C
Below 90% RH (non-frosting)
1.0 G when smaller than 20 Hz; 0.6 G when between 20–60 Hz
Fan cooling
Below 1,000 m (free from dust, corrosive gases and liquids)
8-3