Delta IED-S Series User Manual page 70

Integrated elevator drive
Table of Contents

Advertisement

Terminal
Terminal
Socket
+24V
External power input +24 V
+24V
TB5
DCM
External power input 0 V
DCM
TB8
STO (Safe Torque Off)
AI
Analog voltage input port
TB1
Analog control signal common
ACM
terminal
Common terminal for R1A and R2A
R12C
contactors
R1A
Operation contactor [SW]
R2A
Brake-1 contactor [BY1]
R3A
Brake-2 contactor [BY2]
R3B
R4A
Main landing at fire emergency
[FIRLD]
R4B
TB6
R5A
Brake contactor for full voltage [BY4]
R5B
R6A
Master fan [MFN]
R6B
R7A
Rope gripper contactor [RG]
R7B
R8A
Door unlock contactor [SY]
R8B
HVX1
Safety hatch [SFH]
HVC1
HVX2
TB7
Gate safety hatch [GSH]
HVC2
HVX3
Layer door safety hatch [DSH]
HVC3
HVX4
Emergency operation [EIS]
HVC4
TB9
HVX5
External reset device [RESET]
HVC5
Default Setting
DC
5-5
Chapter 5 Control Terminals | IED-S
Description
24 V, 800 mA
Power cut-off safety function EN954-1 and
IEC/EN61508
Range: -10–10 V
DC
User-defined function
Common terminal for analog control signal
Multi-function relay output port:
(1) User-defined function
(2) Resistive load
5A / 4A 250 V
/ 30 V
AC
(3) Inductive load (COS 0.4)
3A / 2A 250 V
/ 30 V
AC
User-defined function
Isolated photocouper input
Input impedance: 20kΩ
Rated: 110 V
/ 5.5 mA or 110 V
AC
Voltage > 88 V
when DC is guaranteed to be
DC
activated (ON);
Voltage < 50 V
when DC is guaranteed to be
DC
deactivated (OFF).
Voltage > 88 V
when AC is guaranteed to be
AC
activated (ON);
Voltage < 50 V
when AC is guaranteed to be
AC
deactivated (OFF).
DC
DC
/ 5.5 mA
DC

Advertisement

Table of Contents
loading