Chapter 12 Descriptions of Parameter Settings | IED-S
 Sets the elevator's mode.
 LED display
Font Door Status
Settings
 Sets the status for the front door.
 LED display
Rear Door Status
Settings
bit 10: Security floor
bit 11: Mode of stop at each floor
bit 12: Car call password
bit 13: Medical recall running
bit 14: Goods only
bit 15: Group control running
The display for digital keypad KPC-CC01
0000h–FFFFh
bit 0: Front door opens
bit 1: Front door closes
bit 2: Front door is ready to open
bit 3: Front door closes, MO = 102 (CL1)
bit 4: Front door reaches its open position, MI = 100 (OLT1)
bit 5: Front door reaches its closed position, MI = 102 (CLT1)
bit 6: Front door light sensor, MI = 104 (EDP1)
bit 7: Front door safety edge, MI = 106 (SE1)
bit 8: Front door over-torque, MI = 119 (TOEX1)
bit 9: Front door open button, MI = 151 (DOB1)
bit 10: Front door open auxiliary button, MI = 171 (DOB1B)
bit 11: Front door open extended button, MI = 152 (DOBH1)
bit 12: Front door open auxiliary extended button, MI = 172 (DOBH1B)
bit 13: Front door open extended button lamp, MO = 152 (DOBHL1), MO =
172 (DOBHL1B)
bit 14: Front door at this floor can be opened, Pr.05-02–05-05
bit 15: With front door, MI = 115 (HFD)
The display for digital keypad KPC-CC01
0000h–FFFFh
bit 0: Rear door opens
bit 1: Rear door closes
bit 2: Rear door is ready to open
bit 3: Rear door closes, MO = 103 (CL2)
bit 4: Rear door reaches its open position, MI = 101 (OLT2)
bit 5: Rear door reaches its closed position, MI = 103 (CLT2)
bit 6: Rear door light sensor, MI = 105 (EDP2)
bit 7: Rear door safety edge, MI = 107 (SE2)
bit 8: Rear door over-torque, MI = 120 (TOEX2)
12-00-4